Medical-Grade Silicone Body Jewelry: The Polymer Science of Biocompatibility

Key Takeaways:

» Medical-grade silicone is not the same as commercial silicone—the difference is cross-linking chemistry, not marketing

» Platinum-cured silicone leaves no chemical byproducts, making it the gold standard for implant-grade body jewelry

» Silicone is intrinsically nickel-free, latex-free, and plasticizer-free—three advantages over alternative materials in a single polymer

» Autoclave sterilization at 134°C does not melt or degrade medical-grade silicone—the thermal stability of PDMS exceeds 300°C

---

Body jewelry sits at a unique materials-engineering intersection: it must be chemically inert enough for prolonged mucosal contact, mechanically durable enough for daily wear, and cleanable to surgical standards. Few materials satisfy all three constraints. Titanium does. Niobium does. And—contrary to the skepticism silicone sometimes attracts—medical-grade polydimethylsiloxane does.

The confusion is understandable. "Silicone" describes everything from $2 kitchen spatulas to FDA-approved breast implants. The polymer backbone is the same—alternating silicon-oxygen bonds with methyl side groups—but the manufacturing pathway determines whether the final product is body-safe or a dermatitis trigger. What follows separates the chemistry from the marketing.

Platinum-Cured vs Peroxide-Cured Silicone: The Polymer Science of Biocompatibility
Infographic: Platinum-Cured vs Peroxide-Cured Silicone: The Polymer Science of Biocompatibility

The Chemistry That Matters: Platinum-Cured vs Peroxide-Cured

Polydimethylsiloxane (PDMS) is formed by cross-linking linear siloxane oligomers into a three-dimensional elastomer network. Two catalyst systems dominate industrial production:

Peroxide-cured silicone uses organic peroxides (typically dicumyl peroxide or benzoyl peroxide) as free-radical initiators. The reaction leaves behind peroxide decomposition products—acetophenone, cumyl alcohol, methane—that must be removed via post-cure baking. Incomplete removal means residual chemicals leach into surrounding tissue. This is the silicone used in bakeware, sealants, and non-medical O-rings. It has no business in a piercing channel.

Platinum-cured (addition-cured) silicone uses a platinum complex catalyst to drive hydrosilylation: vinyl-functional siloxanes react with silicon-hydride cross-linkers, producing the elastomer network with zero chemical byproducts. The reaction is stoichiometrically clean—every vinyl group pairs with a hydride, and nothing is left over. Post-cure processing consists of a simple heat cycle to drive the reaction to completion, not to remove contaminants. This is the silicone required for USP Class VI and ISO 10993 biocompatibility certifications.

The practical difference for a piercer: peroxide-cured silicone contains extractable compounds that trigger contact dermatitis in sensitized individuals. Platinum-cured silicone contains the polymer network and nothing else.

Why Silicone Doesn't Leach

Most body jewelry material concerns center on leaching: nickel ions from stainless steel, phthalate plasticizers from PVC, residual monomers from acrylics. Silicone sidesteps all three mechanisms simultaneously.

No metal ions. The PDMS backbone is silicon-oxygen-silicon—there is no metal in the polymer structure. Silicone cannot release nickel, chromium, or cobalt because it contains none of these elements. This makes it categorically hypoallergenic in the strict chemical sense, not the looser marketing sense.

No plasticizers. PVC and many thermoplastics achieve flexibility by incorporating phthalate plasticizers—small molecules that migrate out over time. Silicone elastomers achieve flexibility through cross-link density control, not plasticizer addition. A 40-durometer Shore A silicone is soft because it has fewer cross-links per unit volume, not because something was added to soften it.

No residual monomer. Chain-growth polymers (acrylics, polystyrene) always contain some fraction of unreacted monomer. Silicone's addition-cure chemistry, by contrast, goes to completion—the hydrosilylation reaction between vinyl and Si-H groups is thermodynamically driven and leaves no monomer behind when properly formulated.

Autoclave Reality: PDMS Thermal Stability

A persistent piece of shop folklore holds that silicone "melts in the autoclave." The claim is physically incorrect. PDMS has a thermal degradation onset above 300°C—well beyond the 134°C of a standard steam autoclave cycle. Medical-grade silicone tubing is routinely autoclaved in surgical settings at 121-134°C for hundreds of cycles without measurable property degradation.

What does happen: low-quality silicone—peroxide-cured, under-cross-linked, or extended with silicone oil—can swell, deform, or develop surface tack after repeated steam exposure. This is not melting. It is the failure mode of an inadequately formulated elastomer. The correct conclusion is not "silicone cannot be autoclaved" but "only platinum-cured, medical-grade silicone should be autoclaved."

Kaplans, reputable body jewelry manufacturers, and ASTM-grade material suppliers all sell autoclave-stable silicone products. The material handles it. The question is whether the specific piece in your hand was made from the right grade.

Practical Identification for Studios

Studios purchasing silicone jewelry should demand documentation verifying:

1. Platinum-cured designation—explicitly stated, not just "medical grade"
2. ISO 10993-5 (cytotoxicity) and ISO 10993-10 (sensitization) test reports
3. USP Class VI certification or equivalent biological reactivity classification
4. Batch traceability—a lot number linking the finished piece to the raw material certificate

If a supplier cannot produce these documents, the silicone grade is unverified. The piece might be platinum-cured. It might be peroxide-cured with aggressive post-processing. Without the paper trail, there is no way to know.

---

Frequently Asked Questions

Is silicone body jewelry safe for initial piercings?

Medical-grade, platinum-cured silicone with valid ISO 10993 certification is accepted for initial piercing in the jewellery guidelines of the Association of Professional Piercers (APP), a US trade association, when used in appropriate gauges and designs. The key qualifier is "medical-grade"—unverified silicone should never be used in a fresh piercing.

Does silicone contain latex?

No. Silicone rubber and natural rubber latex are chemically unrelated. Latex allergy is a Type I hypersensitivity to proteins found in natural rubber (Hevea brasiliensis). Silicone is a synthetic polymer containing no proteins and does not cross-react with latex antibodies.

Can I stretch my ears faster with silicone tunnels?

No—and this is a common misconception. Silicone's low surface friction can make stretching feel easier, but the tissue needs the same minimum healing time regardless of jewelry material. Rapid stretching with any material increases the risk of blowouts, micro-tears, and scar tissue formation. Follow the standard 4-8 week waiting period between stretches.

What's the difference between "body-safe" and "implant-grade" silicone?

"Body-safe" has no regulatory definition—it is marketing language. "Implant-grade" is more meaningful but still requires verification: the material should meet USP Class VI (systemic injection, intracutaneous, and implantation tests) and ISO 10993-1 biological evaluation. If the supplier cannot provide the test standard and certifying laboratory, treat "implant-grade" as a claim, not a fact.

Does silicone jewelry degrade over time?

Medical-grade platinum-cured silicone is highly resistant to hydrolysis, UV degradation, and oxidation. In normal body jewelry use—intermittent wear, regular cleaning, storage away from direct sunlight—a quality silicone piece should last years without measurable degradation. The common failure mode is mechanical (tearing at thin edges or tight radii), not chemical.

References

1. Mojsiewicz-Pieńkowska K et al. "Direct human contact with siloxanes (silicones)—safety or risk." Frontiers in Pharmacology, 2016; 7: 132. PMID 27242531
2. ISO 10993-1:2018. Biological evaluation of medical devices—Part 1: Evaluation and testing within a risk management process. International Organization for Standardization.
3. United States Pharmacopeia. <88> Biological Reactivity Tests, In Vivo. USP-NF. Current Edition.
4. Colas A, Curtis J. "Silicone Biomaterials: History and Chemistry." In: Biomaterials Science: An Introduction to Materials in Medicine, 2nd ed. Elsevier Academic Press, 2004.
5. Association of Professional Piercers. "Jewelry for Initial Piercings." APP Procedure Manual, 2023 Edition.

6. Why Silicone Biocompatibility Matters for Body Jewelry

When I first started working with medical-grade polymers 25 years ago, "silicone biocompatibility" wasn't a phrase most piercers used. Today, it's the first thing I check when evaluating any material that touches a healing piercing. The term itself refers to how a material interacts with living tissue — whether it triggers inflammation, allergic response, or cellular rejection. For silicone body jewelry, biocompatibility isn't a marketing label; it's a measurable property determined by cross-linking chemistry, residual catalyst levels, and surface stability.

Platinum-cured PDMS (polydimethylsiloxane) is the only silicone I trust for long-term wear. The platinum catalyst drives a hydrosilylation reaction that consumes all reactive groups, leaving no peroxide byproducts, no leachable plasticizers, and no nickel — because nickel isn't part of the formulation. Peroxide-cured silicone, by contrast, can leave acidic residues that irritate tissue. The same logic, a formulation with nothing left in it to leach, is why I built BioFlex® on a medical-grade polypropylene random copolymer (PP-R) rather than a silicone or a cheaper alternative.

If you're researching biocompatibility for a paper or a piercer's reference, you need more than a supplier's claim. I keep a published list of studies on polymer-tissue interaction, autoclave stability, and REACH compliance on our site. The key takeaway: biocompatibility is chemistry, not a certificate. A material either leaches or it doesn't; a surface either supports epithelial cell attachment or it doesn't. Platinum-cured silicone passes those tests. Peroxide-cured often fails.

For piercers and body art professionals, the practical rule is simple: ask for the curing method and the residual catalyst data. If a supplier can't provide that, you're not buying medical-grade silicone — you're buying commercial silicone with a medical-sounding label. That's the gap I built BioFlex® to close.

If you want to see the full polymer specification or compare BioFlex® against other materials, start with our BioFlex® technical page or use our sizing and material tools to match the right jewelry to the piercing. Biocompatibility should be verifiable, not assumed.

Mind map · Silicone Biocompatibility: The Polymer Science Behind Body Jewelry

  • Medical-Grade Silicone Biocompatibility
    • Cross-Linking Chemistry

      Platinum-curing drives hydrosilylation with zero chemical byproducts, while peroxide curing leaves volatile residues that can leach into surrounding tissues.

      • Platinum Curing
        • Addition-Curing Hydrosilylation
        • Zero Chemical Byproducts
      • Peroxide Curing
        • Volatile Organic Acids
        • Post-Cure Baking Needs
    • Inherent Biocompatibility Advantages

      Medical-grade silicone is intrinsically nickel-free, latex-free, and contains no phthalate plasticizers or unreacted residual monomers.

      • Nickel and Metal Free
      • No Small-Molecule Plasticizers
      • No Residual Monomers
    • Autoclave Sterilization Stability

      Polydimethylsiloxane has a thermal degradation onset above 300°C, allowing medical-grade silicone to withstand steam autoclaving at 134°C without degradation.

      • Steam Autoclave Resistance
      • Extreme Heat Threshold
    • Regulatory Sourcing Standards

      Safe medical-grade silicone must possess documentation verifying USP Class VI compliance, ISO 10993 cytotoxicity testing, and raw material batch traceability.

      • USP Class VI Compliance
      • ISO 10993 Biocompatibility
      • Lot Batch Traceability
    • Piercing and Stretching Guidelines

      Unverified silicone must never be used in fresh piercings, and ear stretching requires minimum healing periods of four to eight weeks.

      • Initial Piercing Rules
      • Stretching Recovery Timeline
StructureProcessMaterialHazard

5 branches, 0 sources. Each branch cites the article it came from; the labels beneath it are names, not claims.

Silicone Chemistry Quiz

  1. 1. What chemical reaction mechanism forms platinum-cured silicone without producing chemical byproducts?

    • ✓ Hydrosilylation of vinyl-functional siloxanes with silicon-hydride cross-linkers — Addition-cure hydrosilylation pairs vinyl groups with silicon hydrides stoichiometrically, leaving no residual compounds.
    • • Free-radical initiation using dicumyl or benzoyl peroxide — Organic peroxide initiators are used in peroxide-cured systems and generate chemical decomposition byproducts that require post-cure baking.
    • • Chain-growth polymerization of acrylic oligomers — Chain-growth polymerization is typical of acrylic materials rather than addition-cured siloxane networks.
    • • Hydrolytic cross-linking driven by silicone oil extension — Silicone is highly resistant to hydrolytic cleavage, and silicone oil extension is an additive practice rather than a curing mechanism.
  2. 2. Why is medical-grade silicone intrinsically free of nickel and other metal ions?

    • ✓ The polymer backbone consists strictly of alternating silicon and oxygen atoms with methyl side groups. — The polydimethylsiloxane backbone consists purely of silicon, oxygen, and methyl groups, making metal leaching chemically impossible.
    • • High-temperature post-cure baking evaporates trace metallic contaminants from the matrix. — Post-cure baking removes organic peroxide byproducts in peroxide-cured silicone, not metal ions from an inherently metal-free polymer.
    • • Platinum complexes added during curing selectively bind and neutralize metal ions. — Platinum acts strictly as a hydrosilylation catalyst for cross-linking siloxanes rather than a heavy metal neutralizing agent.
    • • Cross-linking density control eliminates the space required for metal ions to form. — Cross-link density determines mechanical softness and elasticity rather than preventing metal ion contamination.
  3. 3. How do silicone elastomers achieve flexibility without requiring added phthalate plasticizers?

    • ✓ Through precise control of cross-link density in the polymer network. — Adjusting the frequency of cross-links per unit volume directly regulates the stiffness or softness of the elastomer.
    • • By blending low-viscosity silicone oils into the cross-linked matrix. — Adding silicone oil extends low-quality silicone but leads to instability rather than safe plasticizer-free flexibility.
    • • Through post-cure thermal processing that loosens polymer backbone bonds. — Thermal post-curing completes cross-linking reactions rather than breaking backbone bonds to soften the material.
    • • By incorporating unreacted chain-growth monomers to soften the structure. — Monomer presence is a flaw of chain-growth polymers like acrylics, whereas silicone flexibility relies on controlled cross-linking.
  4. 4. What causes low-quality silicone to swell or deform during steam autoclaving at 134°C?

    • ✓ Improper formulation, such as peroxide curing, insufficient cross-linking, or silicone oil extension. — Impurities, unreacted peroxide byproducts, or added silicone oils alter material stability under high-temperature steam.
    • • Reaching the fundamental thermal degradation onset temperature of polydimethylsiloxane. — PDMS has a thermal degradation onset exceeding 300°C, which is far higher than standard steam autoclave temperatures.
    • • Polymer backbone breakdown driven by intense moisture contact and high pressure. — Medical-grade silicone is exceptionally resistant to hydrolysis, making moisture breakdown an unlikely cause of swelling.
    • • Complete melting of the siloxane oligomers within standard autoclave cycles. — Steam exposure causes surface tack or swelling in poor formulations, but true melting does not occur at 134°C.
  5. 5. Which combination of biological test reports and certifications provides valid documentation of medical-grade platinum-cured silicone safety?

    • ✓ ISO 10993-5 (cytotoxicity), ISO 10993-10 (sensitization), and USP Class VI testing. — Cytotoxicity, sensitization, and biological reactivity testing represent the established standard certifications for verified medical silicone.
    • • ISO 9001 quality compliance, OSHA bloodborne safety standards, and FDA food-grade approval. — OSHA and general ISO quality management standards address workplace safety and manufacturing processes rather than biological material safety.
    • • ASTM F136 material specifications and REACH chemical registration documentation. — ASTM F136 applies to implant-grade titanium alloys rather than siloxane polymer biocompatibility testing.
    • • ISO 13485 medical device manufacturing standards and REACH extractable testing. — ISO 13485 covers quality management system requirements for medical device manufacturers rather than material biological safety testing.
  6. 6. Which chemical decomposition products are left behind in peroxide-cured silicone if post-cure baking is incomplete?

    • ✓ Acetophenone, cumyl alcohol, and methane. — Organic peroxides like dicumyl or benzoyl peroxide decompose during vulcanization into these specific volatile organic compounds.
    • • Vinyl monomers, hydride cross-linkers, and platinum salts. — Vinyl groups and hydride cross-linkers are components of clean platinum-cured addition chemistry, not peroxide decomposition.
    • • Phthalate plasticizers, acrylic monomers, and cobalt ions. — Phthalates are plasticizers used in PVC, and cobalt ions are metallic elements absent from siloxane formulations.
    • • Silicon dioxide, formaldehyde, and nitric acid. — Peroxide curing involves organic radical reactions rather than reactions producing nitric acid or pure silicon dioxide byproducts.
  7. 7. What is the primary purpose of post-cure thermal processing in platinum-cured silicone manufacturing?

    • ✓ Driving the hydrosilylation reaction to complete consumption of reactive groups. — Heat processing ensures that all vinyl and silicon-hydride functional groups complete their reaction within the network.
    • • Evaporating residual peroxide decomposition products and volatile acids. — Driving off volatile acid and peroxide decomposition byproducts is required for peroxide-cured silicone, not platinum-cured systems.
    • • Softening the elastomer by breaking down dense cross-link nodes. — Thermal post-curing stabilizes the three-dimensional cross-linked network rather than degrading nodes to reduce hardness.
    • • Removing unreacted chain-growth monomers from the finished polymer. — Platinum-cured hydrosilylation does not proceed via chain-growth monomers, eliminating residual monomer issues.
  8. 8. What is the correct guidance regarding the waiting period for stretching earlobes with silicone tunnels?

    • ✓ Tissues require a waiting period of 4 to 8 weeks between stretches, regardless of jewelry material. — Tissue expansion requires adequate time for cell division and healing regardless of how easily jewelry slides.
    • • Low surface friction allows stretching intervals to be reduced safely to 1 to 2 weeks. — Low surface friction reduces mechanical resistance during insertion but does not speed up physiological tissue healing.
    • • Stretching speed can be increased as long as the silicone possesses USP Class VI certification. — Material biocompatibility certifications ensure non-toxicity but do not accelerate cellular tissue remodeling.
    • • Silicone tunnels should be expanded rapidly to prevent epithelial cell attachment to the jewelry. — Rapid stretching increases risks of blowouts and micro-tears rather than preventing jewelry adhesion.
  9. 9. How does the source material distinguish between 'body-safe' and 'implant-grade' silicone?

    • ✓ 'Body-safe' is an unregulated marketing term, whereas 'implant-grade' requires verification against USP Class VI and ISO 10993 standards. — 'Body-safe' lacks formal legal definitions, whereas 'implant-grade' requires empirical biological reactivity testing under recognized standards.
    • • 'Body-safe' refers specifically to peroxide-cured materials, while 'implant-grade' refers to platinum-cured materials. — Peroxide-cured silicone is unsuitable for piercings, while platinum curing is required for biocompatible medical grades.
    • • 'Implant-grade' is an informal trade term, while 'body-safe' is a standard legally defined by medical regulators. — 'Body-safe' is an unregulated marketing phrase, while 'implant-grade' references specific biological testing standards.
    • • 'Body-safe' silicone can withstand temperatures above 300°C, whereas 'implant-grade' silicone degrades at 134°C. — Medical-grade silicone retains structural stability beyond 300°C regardless of which marketing term is used.
  10. 10. What is the primary long-term failure mode for quality platinum-cured medical-grade silicone body jewelry?

    • ✓ Mechanical failure, such as tearing at thin edges or tight radii. — Thin structural geometries and tight radii concentrate stress, making tearing the primary failure mechanism.
    • • Chemical degradation driven by ultraviolet radiation exposure. — Platinum-cured PDMS exhibits high resistance to ultraviolet light and atmospheric oxidation during normal wear.
    • • Structural breakdown caused by bodily fluid hydrolysis over time. — Siloxane bonds are inherently hydrolysis-resistant, making breakdown from bodily fluids extremely rare.
    • • Gradual leaching of hazardous unreacted monomers into surrounding tissue. — Properly formulated addition-cured silicone contains no residual monomer to leach over time.
  11. 11. Why does medical-grade silicone not induce allergic reactions in individuals with natural latex allergies?

    • ✓ It is a synthetic polymer completely free of proteins and does not cross-react with latex antibodies. — Synthetic silicone contains no plant-derived proteins, preventing cross-reactivity with antibodies that trigger natural latex allergies.
    • • The platinum catalyst alters rubber proteins so they are unrecognizable to the immune system. — Platinum functions solely as a cross-linking catalyst and does not interact with or neutralize organic rubber proteins.
    • • High-temperature post-cure baking neutralizes any latex proteins present in the raw materials. — Silicone formulations do not contain natural rubber or plant proteins at any stage of manufacturing.
    • • Cross-link density control encapsulates allergen proteins to prevent tissue contact. — Silicone achieves elasticity without proteins or latex additives, rendering encapsulation unnecessary.
  12. 12. What is the position of the Association of Professional Piercers (APP) regarding the use of silicone in initial piercings?

    • ✓ The association approves medical-grade, platinum-cured silicone with valid ISO 10993 certification for initial piercings in appropriate gauges and designs. — The APP accepts certified medical-grade platinum-cured silicone for initial piercings when appropriate gauge and design criteria are met.
    • • The association strictly prohibits all silicone materials in fresh piercings due to tissue adhesion risks. — The APP does not ban certified medical-grade silicone for initial wear, provided material and design specifications are satisfied.
    • • The association requires that initial piercing jewelry be made of peroxide-cured silicone with post-cure baking documentation. — Peroxide-cured silicone contains leachable residual compounds and is not suitable or recommended for initial piercings.
    • • The association mandates that silicone only be used after a minimum waiting period of 8 weeks post-piercing. — Qualified medical-grade silicone can be worn in fresh piercings without requiring a mandatory waiting period if correctly sized.

Extended Reference Table

8 of 8 rows

Extended reference table generated from the article and its verified research sources. Bracketed numbers jump to the matching entry in the Technical References below.

SafetyItem or Practice Material Class Primary Characteristics Curing Catalyst or Mechanism Regulatory Standards and Compliance Common Applications Source
✅Platinum-Cured SiliconeSilicone Elastomer (HCR/LSR)High purity, excellent transparency, no odor or flavor-impairing byproducts, and non-yellowing. Low extractables (<50 ppm), nickel-free, and thermal stability exceeding 300°C.Platinum-catalyzed addition curing (Si-H groups + vinyl groups)ISO 10993, USP Class VI, FDA 21 CFR 177.2600, BfRMedical-grade implants, catheters, pharmaceutical seals, surgical tubing, and premium body jewelry.[7]
✅Peroxide-Cured SiliconeSilicone Elastomer (HCR)Cost-effective, often hazy or opaque with a tackier feel. May contain organic acid by-products, volatile organic compounds, or "bloom" residues. Potential dermatitis trigger.Free-radical reaction initiated by organic peroxides (e.g., dicumyl or benzoyl peroxide)FDA 21 CFR 177.2600Industrial gaskets, automotive seals, HVAC dampers, and household appliance seals.[7]
✅Titanium (Alloy and Pure)Metallic Element/AlloyBiocompatible, high strength, non-toxic, and corrosion-resistant. Lightweight and can be anodized for color. Preferred for nickel sensitivity.Not applicable (Metal)ASTM F136, ASTM F67, ASTM F1295, ASTM F86, ISO 5832-3Initial piercings, orthopedic implants, and threadless body jewelry.
✅316L Stainless SteelMetallic AlloyLow carbon version of 316 steel; contains approx. 15% nickel. Corrosion resistance depends on chromium oxide layer. Durable and capable of mirror polish.Not applicable (Metal)ASTM F138, ISO 5832-1, ISO 10993-(6, 10, or 11), EEC Nickel DirectiveSurgical staples, wires, single flare plugs, and internally threaded eyelets.
✅Autoclave SterilizationSterilization PracticeUses saturated steam under high pressure (typically 121-134°C) to destroy bacterial spores. Leaves no harmful residues.Heat and PressureISO 17665, EN 285Preparing medical tools, surgical instruments, and biocompatible jewelry for procedures.[7]
⚠️ISO 10993Testing StandardInternational framework for biological safety testing, including cytotoxicity, sensitization, and systemic toxicity.Not applicableISO 10993-1, ISO 10993-5, ISO 10993-10Verification of material safety for human tissue contact and medical devices.[7]
✅USP Class VITesting StandardStringent biological reactivity testing involving systemic injection, intracutaneous, and implantation tests.Not applicableUSP General Chapter <88>Certification for long-term or implantable medical applications and pharmaceutical equipment.[7]
✅Ear StretchingBody Modification PracticeIncremental enlargement of a piercing; results in a healing wound with each size increase. Requires 4-8 week waiting periods to avoid micro-tears.Mechanical tension-Modification of earlobes using plugs, eyelets, or silicone tunnels.

Free Body Art Wall Posters

Print-ready reference posters for your studio or your own wall. Free to download and display, embed on your own site with attribution. Click any poster to preview it full size before downloading.

Choose and download all 19 posters

Technical_References_Archive

  • [1]Mojsiewicz-Pieńkowska K et al. "Direct human contact with siloxanes (silicones)—safety or risk." Frontiers in Pharmacology, 2016; 7: 132. doi.org/10.3389/fphar.2016.00132
  • [2]ISO 10993-1:2018. Biological evaluation of medical devices—Part 1: Evaluation and testing within a risk management process. International Organization for Standardization. standard catalogue
  • [3]United States Pharmacopeia. <88> Biological Reactivity Tests, In Vivo. USP-NF. Current Edition. doi.usp.org/USPNF/USPNF_M98834_01_01.html
  • [4]Colas A, Curtis J. Silicones. In: Ratner BD, Hoffman AS, Schoen FJ, Lemons JE, eds. Biomaterials Science: An Introduction to Materials in Medicine. 3rd ed. Elsevier Academic Press, 2013:82-91. [doi:10.1016/B978-0-08-087780-8.00010-3](https://doi.org/10.1016/B978-0-08-087780-8.00010-3)
  • [5]Association of Professional Piercers. "Jewelry for Initial Piercings." APP Procedure Manual, 2013 edition (p. 28). APP Procedure Manual (PDF)
  • [6]PMID 42181028 Mora-Leiva et al. Systematic biocompatibility assessment of 4-µm surface silicone implants.. Biomater Biosyst. 2026;22:100138.
  • [7]Jewelry for Initial Piercings - Association of Professional Piercers: safepiercing.org/jewelry-for-initial-piercings

About the Author

PP

Patrick Poli

Chief Engineer, Poli International · Creator of BioFlex® body jewelry

Patrick has spent 25+ years manufacturing body jewellery and studio equipment, and is the creator of BioFlex® body jewelry. He developed antimicrobial silver-ion body jewellery with Clariant’s polymer laboratory, years before a pandemic made the idea obvious. He also spent two years developing it as a PP-R random copolymer, tested to ISO 10993 and built on a USP Class VI resin.