Seeing Under Ink: The Physics of Ultrasound and Photoacoustic Tattoo Imaging

PP

Chief Engineer

Patrick Poli

Journal Date

2026-10-04

Last Reviewed

2026-10-08

Ink ends up one to three millimetres below a surface nobody can see through, and that fact explains most of the guesswork in tattooing. Whether a design will hold, why one colour fades faster, why a reaction appears months later, and how much pigment a laser can reach are all depth questions. Two imaging modalities answer them with measurable physics instead of judgement: high-frequency ultrasound reconstructs structure from reflected sound, and photoacoustic imaging converts absorbed light back into sound to read the pigment itself.

Why Ink Is a Depth Problem, Not a Colour Problem

The epidermis is thin, but not uniformly thin. A systematic review pooling 142 studies across 37 skin areas found epidermal thickness ranging from 31.2 micrometres on the penis to 596.6 micrometres on the plantar foot. High-frequency ultrasonography produced systematically higher values than histology and optical coherence tomography, a reminder that every modality measures its own version of thickness. [6]

Pigment does not stop at a fixed depth either. A histological study of tattooed male skin demonstrated statistically significant relationships between the depth of pigment deposition and age, dermis thickness, epidermis thickness and tattoo location. Needle depth is a machine setting; final pigment depth is a biological outcome. [5]

Laser physics cares about the same variable. Tattoo removal fragments solid pigment particles with short, intense pulses, and fragmentation only occurs where fluence is still high enough at the particle. [8] Misjudge depth and the pulse either misses the target or deposits energy somewhere you did not intend.

Ultrasound: Impedance, Echo Density, and the Resolution Trade-off

A transducer emits short pulses of sound and listens for reflections. Reflections occur wherever acoustic impedance, the product of density and speed of sound, changes, which is why the dermis-to-ink interface, the fascia and water-rich inflammation each return a different echo. Sound travels at roughly 1,540 metres per second in soft tissue, so a 20 MHz probe operates with a wavelength near 77 micrometres and an axial resolution of roughly half that, about 38 micrometres. Resolution improves as frequency rises, but attenuation climbs with it, on the order of 0.5 decibels per centimetre per megahertz, so penetration falls. High-frequency ultrasound is conventionally defined as 10 MHz and above and can image from the stratum corneum to the deep fascia. [1]

The 20 MHz Signature of a Tattoo Reaction

The clearest clinical dataset on tattoo ultrasound comes from a Danish study of 73 people with adverse tattoo reactions, 58 with punch biopsies for comparison. On 20 MHz ultrasonography, affected skin was on average 0.73 mm thicker than the same person's control skin, and a prominent echolucent band averaged 0.89 mm thick. That darker band sits in the outer dermis because cellular infiltrate is water-rich and scatters less sound than dense collagen, and it extends deeper as reactions become more severe. Band thickness correlated with the depth of cellular infiltration measured microscopically at R = 0.6412 (P < 0.001). [2]

That is an objective severity score obtained without cutting anything, and it comes with an honest limit. Granulomatous and pseudolymphomatous reactions showed no distinguishing ultrasound features, so imaging measures how much and how deep, not which disease. Biopsy remains the reference standard, and ultrasound is most useful for choosing where to take it and for tracking change. A case report later paired high-frequency ultrasound with line-field optical coherence tomography on a delayed reaction to red dye, showing how the modalities stack rather than compete. [7]

Photoacoustics: When Pigment Absorbs Light, Sound Comes Back

Photoacoustic imaging runs the chain in reverse. A nanosecond light pulse is absorbed by a chromophore, the absorber expands thermoelastically, and that expansion radiates a broadband acoustic wave an ordinary ultrasound transducer can receive. The result is optical contrast read out at acoustic resolution, and by construction it is pigment-selective. [3]

In a combined phantom and clinical evaluation, ten commercial tattoo inks were characterised in vitro and an intradermal wrist tattoo was imaged in vivo. Black, grey, green, violet and blue pigments produced high photoacoustic signal, while white, orange, red and yellow produced comparatively little, because signal amplitude tracks the absorption coefficient at the chosen wavelength. The authors proposed the technique as a preoperative adjunct for delineating tattoo extent and, potentially, for guiding or monitoring laser removal. [3]

That wavelength dependence explains a familiar complaint. Inks that absorb poorly at the treatment wavelength are difficult for a laser to clear, and they are the same inks that image faintly. The colour that will not budge and the colour that will not show up are one physical property seen from two sides.

Tattoo Tomography: 3D Mapping Without Tracking Hardware

A 2021 engineering study tackled the limited field of view of handheld probes. The team placed a printed optical pattern on the skin, recovered the probe pose from a single image of that pattern, and used it as a global coordinate frame to compound freehand slices into a three-dimensional volume. Reconstruction was assessed on phantoms and on an in vivo forearm without external tracking hardware or application-specific training data. [4]

In practical terms this points at a clinical-room workflow: map an entire tattoo in three dimensions, then compare that map against the depth a laser can treat. The constraints that remain are physical rather than logistical. Light fluence has to stay inside laser safety limits, melanin competes for photons at the skin surface, and usable penetration depends on wavelength and skin type.

ModalityContrast sourceTypical resolutionUseful depthQuestion it answers
High-frequency ultrasound, 10 to 20 MHz and aboveAcoustic impedance changes38 to 77 micrometres axial1 to 2 cmHow thick and how deep is the tissue change
Photoacoustic imagingOptical absorption, acoustic readoutTens of micrometres to sub-millimetreMillimetres to centimetresWhich pigment is where, and how strongly it absorbs
Line-field optical coherence tomographyNear-infrared backscatterMicron scale1 to 2 mmSuperficial cellular detail of a reaction

Clinical Takeaways

1. Treat depth as measured, not assumed. Pigment depth varies with skin thickness, age and body location, and it determines laser clearance. [5]
2. Use ultrasound to quantify a reaction. A mean 0.73 mm thickening and a 0.89 mm echolucent band give an objective severity measure that a photograph cannot. [2]
3. Do not expect imaging to name the disease. Granulomatous and pseudolymphomatous reactions overlap on ultrasound, so biopsy still decides. [2]
4. Expect colour-dependent behaviour in both imaging and removal. Strong absorbers image brightly and fragment well, weak absorbers do neither. [3]
5. Respect the calibration caveat. High-frequency ultrasonography reads skin thickness higher than histology and optical coherence tomography, so track values within one modality over time, not across studies. [6]

The conclusion is unglamorous. The physics that lets us see ink is the same physics that decides whether we can remove it. Depth, absorption and acoustic impedance are the shared variables, and imaging does not replace the biopsy or the laser. It replaces the guessing.


FAQ



How deep does tattoo ink actually sit in the skin?


Tattoo pigment is deposited in the dermis, typically ending up one to three millimetres below the skin surface, but the final depth is not a fixed needle setting. A histological study of tattooed male skin found statistically significant relationships between pigment deposition depth and age, dermis thickness, epidermis thickness, and tattoo location, meaning final pigment depth is a biological outcome rather than a machine parameter. Because laser fragmentation only occurs where fluence remains high enough at the particle, misjudging this depth means the pulse either misses the target or deposits energy in unintended tissue.




Can ultrasound really detect a tattoo reaction or infection?


Yes, high-frequency ultrasound can objectively quantify adverse tattoo reactions without a biopsy. In a Danish study of 73 people with adverse tattoo reactions and 58 punch biopsies for comparison, affected skin was on average 0.73 mm thicker than the same person's control skin on 20 MHz ultrasonography, with a prominent echolucent band averaging 0.89 mm thick that correlated with microscopically measured cellular infiltration depth at R = 0.6412 (P < 0.001). The technique has an honest limit, however: granulomatous and pseudolymphomatous reactions show no distinguishing ultrasound features, so imaging measures how much and how deep the reaction is, not which disease it is.




What is photoacoustic tattoo imaging and how does it work?


Photoacoustic imaging reverses the ultrasound chain: a nanosecond light pulse is absorbed by a chromophore such as tattoo pigment, causing the absorber to expand and generate sound that can be detected and reconstructed into an image. Unlike high-frequency ultrasound, which reconstructs structure from reflected sound based on acoustic impedance changes, photoacoustic imaging reads the pigment itself by converting absorbed light back into sound. This makes it a complementary modality for characterising ink composition and distribution rather than just tissue architecture.




What frequency ultrasound is used for imaging tattoos and skin?


High-frequency ultrasound, conventionally defined as 10 MHz and above, is used for skin and tattoo imaging and can resolve structures from the stratum corneum down to the deep fascia. Because sound travels at roughly 1,540 metres per second in soft tissue, a 20 MHz probe operates with a wavelength near 77 micrometres and an axial resolution of roughly 38 micrometres. Resolution improves as frequency rises, but attenuation climbs on the order of 0.5 decibels per centimetre per megahertz, so penetration falls as resolution improves.




Why does ultrasound resolution matter so much for studying tattoos?


Resolution determines whether you can distinguish the dermis-to-ink interface, fascia, and water-rich inflammation, each of which returns a different echo because of changes in acoustic impedance (the product of density and speed of sound). At 20 MHz, an axial resolution of roughly 38 micrometres allows fine structural detail, which is why the Danish study could detect an echolucent band averaging 0.89 mm thick and link it to microscopic infiltration depth. Higher frequencies sharpen this picture further but sacrifice penetration, so probe selection is always a trade-off between seeing fine detail and reaching deeper structures such as the deep fascia.



Mind map · Seeing Under Ink: The Physics of Ultrasound and Photoacoustic Tattoo Imaging

  • Seeing Under Ink
    • Depth Problem

      Epidermal thickness and pigment deposition depth vary across body locations and individuals. [Seeing Under Ink: The Physics of Ultrasound and Photoacoustic Tattoo Imaging]

      • Epidermal Thickness Variation
        • Plantar Foot Thickness
      • Deposition Depth Factors
    • High-Frequency Ultrasound

      High-frequency ultrasound detects acoustic impedance changes between skin layers to map structure. [Seeing Under Ink: The Physics of Ultrasound and Photoacoustic Tattoo Imaging]

      • Acoustic Impedance Matching
      • Frequency Resolution Tradeoff
    • Tattoo Reaction Signatures

      Adverse tattoo reactions cause dermal thickening and produce an echolucent band on ultrasound. [Seeing Under Ink: The Physics of Ultrasound and Photoacoustic Tattoo Imaging]

      • Echolucent Band Measurement
      • Biopsy Requirement Limit
    • Photoacoustic Imaging

      Nanosecond laser pulses induce thermoelastic expansion in pigments, generating detectable acoustic waves. [Seeing Under Ink: The Physics of Ultrasound and Photoacoustic Tattoo Imaging]

      • Thermoelastic Expansion Principle
      • Pigment Absorption Signals
    • Three-Dimensional Tattoo Tomography

      Printed optical skin patterns enable 3D ultrasound volume reconstruction without external tracking hardware. [Seeing Under Ink: The Physics of Ultrasound and Photoacoustic Tattoo Imaging]

      • Optical Pattern Pose Recovery
      • Freehand Volume Reconstruction
StructureProcessMaterialHazard

5 branches, 0 sources. Each branch cites the article it came from; the labels beneath it are names, not claims.

Skin Imaging Quiz

  1. 1. Why do measurements of epidermal thickness vary when using high-frequency ultrasonography compared to histology or optical coherence tomography?

    • ✓ High-frequency ultrasonography systematically yields higher thickness values because each modality measures its own physical representation of tissue depth. — High-frequency ultrasonography interacts with acoustic impedance boundaries rather than optical scattering or processed histological tissue, producing systematically higher thickness values.
    • • Histology systematically overestimates thickness because tissue fixation inflates the cellular matrix of the epidermis. — Histology produces systematically lower thickness values than high-frequency ultrasound due to tissue processing and shrinkage.
    • • Optical coherence tomography yields higher thickness values due to light scattering in the subcutaneous fat layer. — Optical coherence tomography measures near-infrared backscatter in superficial layers and yields systematically lower thickness measurements than high-frequency ultrasound.
    • • High-frequency ultrasound underestimates thickness because acoustic pulses attenuate entirely within the stratum corneum. — High-frequency ultrasound easily penetrates through the epidermis to the deep fascia, yielding higher rather than lower thickness values.
  2. 2. According to research cited on tattooed male skin, which set of biological factors correlates significantly with the final depth of pigment deposition?

    • ✓ Recipient age, dermis thickness, epidermis thickness, and body location. — Biological variables alter the tissue environment and skin structure, directly determining final pigment placement beyond initial needle settings.
    • • Needle depth setting, ink viscosity, artist technique, and machine speed. — Needle depth and machine settings represent controllable mechanical inputs rather than the biological skin characteristics investigated in the study.
    • • Epidermal thickness, pigment absorption coefficient, speed of sound in tissue, and recipient age. — Speed of sound and optical absorption coefficients are acoustic and optical physics parameters rather than biological host attributes governing pigment deposition.
    • • Dermis thickness, laser treatment wavelength, skin hydration level, and needle gauge. — Laser wavelength is a parameter of removal physics rather than a biological factor influencing initial anatomical pigment placement.
  3. 3. Given sound velocity in soft tissue of approximately 1,540 m/s, what are the wavelength and estimated axial resolution of a 20 MHz ultrasound transducer?

    • ✓ A wavelength near 77 µm and an axial resolution of roughly 38 µm. — Dividing wave speed by frequency yields a 77 µm wavelength, and axial resolution is approximately half of that wavelength.
    • • A wavelength near 38 µm and an axial resolution of roughly 77 µm. — This option reverses the mathematical relationship where axial resolution is half the acoustic wavelength.
    • • A wavelength near 154 µm and an axial resolution of roughly 77 µm. — Calculating wavelength as speed divided by frequency (1,540 m/s / 20 MHz) yields 77 µm, not 154 µm.
    • • A wavelength near 770 µm and an axial resolution of roughly 380 µm. — These values overestimate the spatial scale of a 20 MHz probe by a factor of ten.
  4. 4. What physical trade-off occurs when transducer frequency is increased to improve spatial resolution in skin ultrasonography?

    • ✓ Signal attenuation increases by roughly 0.5 dB/cm/MHz, which reduces effective penetration depth. — Higher frequency sound waves experience greater acoustic attenuation in soft tissue, limiting imaging depth while improving axial resolution.
    • • Penetration depth increases while acoustic impedance contrast between tissues is lost. — Penetration depth decreases with higher frequencies due to increased tissue attenuation.
    • • The speed of sound in tissue accelerates, causing total acoustic reflection at the epidermal boundary. — The speed of sound in tissue remains approximately constant at 1,540 m/s regardless of transducer frequency.
    • • Axial resolution degrades proportionally with frequency, causing blurred boundary definitions. — Higher frequencies decrease wavelength, which enhances rather than degrades axial spatial resolution.
  5. 5. In clinical ultrasound studies of adverse tattoo reactions, why does the inflammatory cellular infiltrate present as a prominent echolucent band in the outer dermis?

    • ✓ Water-rich cellular infiltrate scatters less sound energy than the dense surrounding collagen network. — Fluid and inflammatory cells present low acoustic scattering relative to fibrous collagen, returning fewer echoes and appearing darker or echolucent.
    • • Pigment particles absorb all acoustic waves completely, preventing sound from reflecting back. — Acoustic reflections depend on density and sound speed differences, whereas pigment absorption of light belongs to photoacoustics.
    • • Dermal collagen undergoes thermoelastic expansion, obscuring normal acoustic reflections. — Thermoelastic expansion is the photon-to-sound mechanism of photoacoustic imaging rather than an ultrasound reflection phenomenon.
    • • Dehydrated immune cells form a rigid barrier that reflects all acoustic energy before reaching the dermis. — Inflammatory infiltrates are water-dense rather than dehydrated, leading to reduced acoustic scattering rather than total specular reflection.
  6. 6. What major diagnostic limitation exists when using 20 MHz high-frequency ultrasound to assess tattoo reactions?

    • ✓ It quantifies the depth and thickness of inflammatory tissue changes but cannot distinguish between granulomatous and pseudolymphomatous pathologies. — Ultrasonic echo patterns reflect structural tissue dimensions and fluid content rather than specific histological cell types or etiologies.
    • • It cannot penetrate beyond the stratum corneum, missing reactions located in the outer dermis. — A 20 MHz probe penetrates several millimeters down to the deep fascia, well past the outer dermis.
    • • It misidentifies dark ink pigment as collagen fibers, creating false measurements of epidermal thickening. — Ultrasound measures acoustic impedance boundaries and inflammatory fluid accumulation without misclassifying pigment as structural collagen.
    • • It requires an invasive punch biopsy prior to imaging to calibrate acoustic reflection speed. — High-frequency ultrasound is completely non-invasive and provides pre-biopsy structural mapping to guide biopsy placement.
  7. 7. Which sequence correctly outlines the physical process involved in photoacoustic tattoo imaging?

    • ✓ Nanosecond light pulse absorption → thermoelastic expansion → broadband acoustic wave emission → ultrasound transducer detection. — Short light pulses excite chromophores to cause rapid expansion, generating pressure waves detected acoustically.
    • • Focused ultrasound pulse emission → impedance reflection ightarrow photon radiation → optical detector readout. — This reverses the signal conversion pathway, as photoacoustics converts absorbed light into sound rather than sound into light.
    • • Continuous optical illumination → pigment photochemical breakdown ightarrow thermal wave generation ightarrow coherence interferometry. — Photoacoustics utilizes nanosecond pulsed excitation for thermoelastic expansion rather than continuous light breakdown.
    • • High-frequency acoustic wave emission → pigment fluorescence excitation ightarrow thermal radiation ightarrow optical readout. — Fluorescence is an optical emission process, whereas photoacoustics relies on acoustic pressure wave generation from optical absorption.
  8. 8. Why do black, grey, green, violet, and blue tattoo inks produce high signal intensity in photoacoustic imaging compared to red, orange, yellow, and white inks?

    • ✓ Photoacoustic signal amplitude directly depends on high optical absorption coefficients at the illumination wavelength. — Chromophores that strongly absorb light at a given wavelength undergo greater thermoelastic expansion, radiating stronger acoustic waves.
    • • Light-colored inks reflect all light into the acoustic detector, saturating the acoustic transducer. — Reflecting light prevents photon absorption, resulting in weak or absent thermoelastic sound generation.
    • • Dark-colored pigments have significantly lower acoustic impedance than surrounding soft tissues. — Contrast in photoacoustics stems from differential light absorption, not intrinsic tissue acoustic impedance contrasts.
    • • Bright pigment colors scatter light into superficial tissue, causing acoustic destructive interference. — Weak signal in lighter pigments is caused by low optical absorption rather than destructive acoustic interference.
  9. 9. How did the 2021 tattoo tomography study compound freehand ultrasound slices into a 3D volume without external tracking hardware?

    • ✓ A printed optical pattern placed on the skin allowed recovery of the probe pose from single camera images to define a global coordinate frame. — Optical tracking of a surface pattern provides the spatial orientation of the handheld probe for image slice compounding without hardware motion sensors.
    • • Deep neural networks were trained on application-specific dataset images to predict hand movement speed. — The study explicitly operated without relying on application-specific training data or neural motion tracking.
    • • Mechanical tracking arms with internal rotary encoders continuously recorded probe trajectory across the arm. — The method was designed specifically for freehand probes without requiring external mechanical or hardware tracking devices.
    • • Line-field optical coherence tomography continuously captured surface movement to calculate acoustic transducer displacement. — Line-field optical coherence tomography is an independent superficial imaging modality, not a tracking mechanism for freehand probes.
  10. 10. According to the clinical summary of skin imaging modalities, what is the primary strength of Line-Field Optical Coherence Tomography (OCT) compared to ultrasound and photoacoustics?

    • ✓ It provides micron-scale resolution of superficial cellular detail in skin reactions down to a depth of 1 to 2 mm. — Line-field OCT uses near-infrared backscatter to achieve high micron-scale resolution in superficial tissue layers.
    • • It measures tissue acoustic impedance shifts from the stratum corneum down to the deep fascia up to 2 cm. — Deep structural imaging down to 2 cm using acoustic impedance contrast is the domain of high-frequency ultrasound.
    • • It identifies specific ink pigments deep in the dermis based on thermoelastic wave generation. — Identifying pigment distribution through thermoelastic wave emission describes photoacoustic imaging.
    • • It eliminates melanin photon competition to map deep tattoo volumes in three dimensions. — Melanin absorption remains a physical photon competition constraint for optical methods, and deep mapping is handled by ultrasound/photoacoustics.

Extended Reference Table

8 of 8 rows

Extended reference table generated from the article and its verified research sources. Bracketed numbers jump to the matching entry in the Technical References below.

SafetyItem or Practice Category Primary Mechanism of Action Target Chromophores or Materials Standards or Clinical Guidance Cites Source
✅High-Frequency Ultrasonography (HF-USG, 20 MHz)Ultrasound ModalityEmission and reception of ultrasound waves above 20 MHz by piezoelectric transducers to visualize B-mode grayscale echogenicity of skin layers up to 8-15 mm depth; measures sound reflections from acoustic impedance changesEpidermis, dermis, subcutaneous tissue, skin tumors, subepidermal low echogenic band (SLEB), acoustic impedance interfacesGuidelines for Performing Dermatologic Ultrasound Examinations (DERMUS group)[9]
✅Ultra High-Frequency Ultrasonography (UHF-USG, 50 MHz)Ultrasound ModalityHigh-frequency ultrasound wave emission achieving higher spatial resolution (20 µm axial, 100 µm lateral)Superficial skin structures and fine anatomical detailsGuidelines for Performing Dermatologic Ultrasound Examinations[9]
✅Color Doppler UltrasoundUltrasound ModalityDetection and mapping of vascular blood flow signals within skin lesions and tissue layersTumor blood vessels, vascular structures in cutaneous growthsGuidelines for Performing Dermatologic Ultrasound Examinations[9]
✅Preoperative Melanoma Thickness AssessmentClinical PracticeUltrasonic measurement of tumor depth and infiltration prior to surgical interventionMelanoma tumor thickness, subepidermal tissue, Breslow depthGuidelines for Performing Dermatologic Ultrasound Examinations[9]
✅Monitoring Atopic Dermatitis with HF-USGClinical PracticeIn vivo non-invasive quantification of subepidermal low echogenic band (SLEB) thickness to assess inflammatory edema and cellular infiltrationSubepidermal low echogenic band (SLEB), dermal inflammatory infiltrates, edemaGuidelines for Performing Dermatologic Ultrasound Examinations[9]
✅Sonographic Staging of Hidradenitis SuppurativaClinical PracticeThree-point sonographic scoring evaluating fluid collections, fistulous tracts, pseudocysts, and dermal thickness alterationsFluid collections, fistulous tracts, pseudocystic nodules, hair follicles, dermisItalian Ultrasound Working Group / Wortsman sonographic scoring system[9]
✅Store-and-Forward (SAF) TeledermatologyClinical PracticeAsynchronous capture, digital storage, and transmission of medical images and patient data for remote expert consultationDigital dermatologic images, ultrasound images, clinical patient recordsWorld Health Organization (WHO) Telemedicine Guidelines[9]
✅Carbon Dioxide Laser (10.6 µm / Continuous / Pulsed)Thermal Laser / Surgical Cutting and VaporizationPhotothermal vaporization, cutting, and tissue drying leading to thermoablation and thermal necrosisWaterBoulnois JL (1986); Thomsen S (1991)

Free Body Art Wall Posters

Print-ready reference posters for your studio or your own wall. Free to download and display, embed on your own site with attribution. Click any poster to preview it full size before downloading.

Choose and download all 40 posters

Technical_References_Archive

  • [1]Levy J, Barrett DL, Harris N, et al. (2021). High-frequency ultrasound in clinical dermatology: a review. Ultrasound J, 13(1), 24. PMID 33877462.
  • [2]Carlsen KH, Tolstrup J, Serup J. (2014). High-frequency ultrasound imaging of tattoo reactions with histopathology as a comparative method. Introduction of preoperative ultrasound diagnostics as a guide to therapeutic intervention. Skin Res Technol, 20(3), 257-264. PMID 24010847.
  • [3]Bolookat ER, Rich LJ, Paragh G, et al. (2020). Photoacoustic imaging of tattoo inks: phantom and clinical evaluation. Appl Sci (Basel), 10(3), 1024. PMID 33604062.
  • [4]Holzwarth N, Schellenberg M, Groehl J, et al. (2021). Tattoo tomography: freehand 3D photoacoustic image reconstruction with an optical pattern. Int J Comput Assist Radiol Surg, 16(7), 1101-1110. PMID 33993409.
  • [5]Olszewska J, Charuta A, Paziewska A, et al. (2023). The relation between the depth of pigment disposition and men's skin thickness, the age and tattoo locations on the body. Histol Histopathol, 38(5), 503-511. PMID 36468542.
  • [6]Lintzeri DA, Karimian N, Blume-Peytavi U, et al. (2022). Epidermal thickness in healthy humans: a systematic review and meta-analysis. J Eur Acad Dermatol Venereol, 36(8), 1191-1200. PMID 35366353.
  • [7]Tognetti L, Ekinde S, Habougit C, et al. (2020). Delayed tattoo reaction from red dye with overlapping clinicopathological features: examination with high-frequency ultrasound and line-field optical coherence tomography. Dermatol Pract Concept, 10(3), e2020053. PMID 32685273.
  • [8]Baeumler W, Weiss KT. (2019). Laser assisted tattoo removal - state of the art and new developments. Photochem Photobiol Sci, 18(2), 349-358. PMID 30452057.
  • [9]High-Frequency Ultrasonography—Possibilities and Perspectives of the Use of 20 MHz in Teledermatology - Frontiers: www.frontiersin.org/journals/medicine/articles/10.3389/fmed.

About the Author

PP

Patrick Poli

Chief Engineer, Poli International · Creator of BioFlex® body jewelry

Patrick has spent 25+ years manufacturing body jewellery and studio equipment, and is the creator of BioFlex® body jewelry. He created the push-fit system so jewellery separates on impact instead of tearing the piercing. He also reworked the push-fit discs in medical-grade soft polymer, EO-sterilised, for people fighting bumps and keloids.